Novus TxIsoUSB Universal Input 2-Wire 4-20mA Head Mount Isolating Transmitter – Precision, Reliability & Noise Immunity

Experience unparalleled signal integrity and precise process control with the Novus TxIsoUSB Head Mount Isolating Transmitter. This advanced 2-wire 4-20mA transmitter is engineered to convert a wide array of industrial sensor inputs into a robust, standard current output, all while providing crucial galvanic isolation to protect your equipment and ensure noise-free data.

Designed for seamless integration into sensor heads (DIN Form B) or junction boxes, the TxIsoUSB offers universal input capability, accepting signals from thermocouples, Pt100, Pt500, Pt1000 RTDs, mV, and V sources. Its innovative USB interface allows for quick, intuitive configuration without the need for external power, making setup and calibration incredibly simple. The built-in isolation ensures that ground loop issues, electrical noise, and hazardous voltages are safely separated, providing stable and reliable measurements even in the most demanding industrial environments.

Key Features & Benefits:

  • Universal Input Flexibility: Accepts a broad range of sensor inputs including Thermocouples (J, K, T, E, N, R, S, B), Pt100/500/1000 RTDs, mV, and V signals. This versatility reduces inventory and simplifies system design.
  • Galvanic Isolation (Input-Output): Provides critical electrical separation between the input and output circuits. This eliminates ground loops, protects connected equipment from surges and transients, and significantly enhances signal integrity in noisy industrial settings.
  • 2-Wire 4-20mA Output: Delivers a standard, robust industrial signal that simplifies wiring, reduces cabling costs, and ensures compatibility with virtually all PLC, DCS, and control systems. It's powered directly from the measurement loop.
  • USB Configurable (No External Power Needed): Features a direct USB port for easy and intuitive configuration via a PC. No complex programming tools or external power supply are required during the setup process, saving time and effort.
  • Compact Head Mount Design: Its small form factor allows it to fit directly into standard DIN Form B sensor heads or junction boxes, protecting connections, saving space, and simplifying wiring in the field.
  • High Accuracy & Stability: Utilizes advanced digital technology for precise measurement conversion, ensuring reliable and consistent data collection over long periods.
  • User-Friendly Configuration Software: Novus's intuitive TxConfig II software (free to download) makes configuring ranges, sensor types, and output settings simple, even for complex applications.
  • Robust Industrial Construction: Built to withstand harsh industrial conditions, ensuring long-term reliability and performance in challenging environments.

Technical Specifications:

  • Input Types:
    • Thermocouples: J, K, T, E, N, R, S, B (Configurable ranges)
    • RTDs: Pt100, Pt500, Pt1000 (2, 3, or 4-wire connections, configurable ranges)
    • Voltage: 0-50mV, 0-100mV, 0-1V (Configurable ranges)
    • Current: 0-20mA (Configurable ranges, via external shunt resistor)
  • Output Signal: 4-20mA (2-wire, loop powered)
  • Output Resolution: 0.25 µA
  • Accuracy: Typically ±0.1% of full scale (varies slightly by input type and range)
  • Galvanic Isolation: 1.5 kVeff (between input and output)
  • Power Supply: 10 to 35 VDC (from the 4-20mA loop)
  • Configuration Interface: Micro USB Type B (via TxConfig II software)
  • Operating Temperature: -40°C to +85°C
  • Housing Material: Polyamide
  • Mounting: Head mount (DIN Form B)
  • Dimensions: Ø44mm (diameter) x 25mm (height) (Typical for head mount)
  • Weight: Approximately 40g
  • Approvals: CE

Ideal Applications:

The Novus TxIsoUSB is an indispensable component for various industries and applications requiring reliable and isolated signal conversion:

  • Industrial Process Control: Chemical, petrochemical, food & beverage, pharmaceuticals, metals, mining.
  • HVAC & Building Automation: Temperature and environmental monitoring in large facilities.
  • Machinery & Equipment Monitoring: Converting sensor data into standard control signals.
  • Remote Data Acquisition Systems: Ensuring signal integrity over long distances or in electrically noisy areas.
  • Water & Wastewater Treatment: Monitoring various process parameters.
  • Test & Measurement: Providing isolated and accurate sensor readings.

Why Choose the Novus TxIsoUSB from Under Control?

At Under Control, we are committed to providing cutting-edge industrial automation and control solutions. The Novus TxIsoUSB stands out for its unmatched combination of universal input flexibility, critical galvanic isolation, and user-friendly USB configuration. It's a reliable, high-performance transmitter that ensures the integrity of your process signals, protecting your valuable equipment and improving data accuracy.

Invest in superior signal conversion and protect your control systems. Add the Novus TxIsoUSB Universal Input 2-Wire 4-20mA Head Mount Isolating Transmitter to your cart today!

Frequently Asked Questions (FAQs):

Q1: What does "isolating transmitter" mean?

A1: An "isolating transmitter" (or galvanic isolation) means that there is no direct electrical connection between the input (where your sensor connects) and the output (where the 4-20mA signal goes). This electrical separation prevents ground loops, protects equipment from voltage surges, and eliminates noise from the signal, ensuring much more accurate and reliable readings.

Q2: What is the benefit of a "2-wire 4-20mA" output?

A2: A 2-wire 4-20mA output means that the transmitter draws its power directly from the current loop itself. This simplifies wiring significantly as only two wires are needed for both power and signal transmission, reducing cabling costs and installation complexity compared to 3-wire or 4-wire systems.

Q3: What types of sensors can I connect to the Novus TxIsoUSB?

A3: This is a universal input transmitter, meaning it's highly versatile. You can connect various types of temperature sensors like Thermocouples (J, K, T, E, N, R, S, B) and RTDs (Pt100, Pt500, Pt1000). It also accepts direct millivolt (mV) and voltage (V) inputs, and can convert current (mA) signals with an external shunt resistor.

Q4: How do I configure the Novus TxIsoUSB transmitter?

A4: Configuration is very easy! You simply connect the transmitter to your computer's USB port using a standard micro USB cable. Then, you use the free Novus TxConfig II software to select your sensor type, input range, and output settings. No external power supply is needed during the configuration process.

Q5: Is this transmitter suitable for hazardous areas?

A5: While the TxIsoUSB offers isolation and is robust, it is not intrinsically safe (Ex-certified) for use in hazardous (explosive) atmospheres. If you require a transmitter for such environments, please ensure you select one with appropriate Ex certifications.

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

DELIVERY TIMES

All orders, wherever possible are shipped the same day within the UK as long as it is received before 1 pm.

Orders placed on Friday after 1 pm or the weekend will be dispatched on Monday.

PACKAGING & SHIPMENT

  • Great care is take with each order to ensure they are packed securely to prevent any damage in transit.
  • We can ship orders in several boxes depending on quantity, size or types.
  • Each order is shipped with a packing note inside the box and a carrier shipping label on the outside.
Water Heating Time Calculator
This calculator works out the length of time it takes to heat a body of water.
Water Heating Time Calculator
Amount of Water
Start Temperature
End Temperature
Heating Power
Efficiency %

0
Water Heating Power Calculator
This calculator works out the power required to heat a body of water.
Water Heating Power Calculator
Amount of Water
Start Temperature
End Temperature
Heating Period
Efficiency %

0
watts
Water Heating Energy Calculator
This calculator works out the energy required to heat a body of water.
Water Heating Energy Calculator
Amount of Water
Start Temperature
End Temperature
Efficiency %

0
Kwh

Drawing

Drawing