Ultra Low Temperature Dry Block/Wet Calibrator(-115℃~50℃)

Prix habituel £10,149.60
Prix habituel Prix soldé £10,149.60
Taxes incluses.
Ultra Low Temperature Dry Block/Wet Calibrator(-115℃~50℃), supplied with flight case and insert. alt_text
  • Apple Pay
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
Prix habituel £10,149.60
Prix habituel Prix soldé £10,149.60

The UCI-SL-AB-CAL Ultra Low Temperature Dry Block/Wet Calibrator (-115℃ to +50℃) provides precise, stable, and uniform temperature calibration for laboratory and on-site applications. Designed for portability and high efficiency, this calibrator allows rapid stabilisation and enhanced calibration speed, making it ideal for a wide range of temperature-measuring instruments, including temperature sensors, standard thermometers, dilatation thermometers, thermocouples, and thermal resistors.

The UCI-SL-AB-CAL solves common issues found in lower-end models, such as slow heat-up times and temperature inaccuracies, delivering faster calibration cycles and superior reliability. Its advanced heating principle ensures rapid heating, stable temperature holding, and quick cooling. Combined with high-precision sensors and touch screen operation, this model offers industry-leading calibration performance while meeting international standards.

Key Features

  • Model: UCI-SL-AB-CAL

  • Ultra-Low Temperature Range: -115℃ to +50℃ for specialized calibration tasks

  • Dual Functionality: Dry block and wet calibration using liquid (e.g., anhydrous ethanol)

  • High Accuracy & Stability: ±0.5℃ accuracy, ±0.05℃/10min full range stability

  • Rapid Heat-Up & Cooling: Max temperature reached in ~10 minutes; minimum temperature in ~90 minutes

  • Dual Input Channels: Simultaneous measurement of reference sensor and sensor under test

  • Automatic Switch Test: Records ramping and switch points automatically

  • Data Logging: USB interface for data transfer and calibration records

  • Portable & Compact: Lightweight design for field and laboratory use

  • Advanced Interface: Intuitive digital touch screen display

  • Safety & Compliance: Over-temperature and short-circuit protection, CE and RoHS certified

Technical Specifications

Parameter Value
Temperature Range -115℃~+50℃
Display Accuracy ±0.5℃ Full range
Display Stability ±0.05℃/10min Full range
Working Condition 0℃~35℃, 30%~80%RH (No condensation)
Altitude <2000m
Working Environment 23℃±2
Insert Depth Insert depth 135mm
Total Depth Total depth 180mm
Insert Diameter 29.8mm
Heating Time -95℃~40℃: 40min
Cooling Time 23℃~-90℃: 40min
Cooling Time 23℃~-115℃: 90min
Stable Time 15min
Resolution 0.01°
Display LCD display, ℃ or ˚F
Dimensions 495mm * 190mm * 280mm (19.5in * 7.5in * 11in)
Weight 16kg
Power (100V~115V) 100V~115V (±10%) 50/60Hz, 575W
Power (200V~230V) 200V~230V (±10%) 50/60Hz, 575W
Fuse (115V) 6.3A T 250V
Fuse (230V) 3.15A T 250V
Communication Interface RS-232 / RS-485
Refrigerant R704 (Helium) <20g, ASHRAE, Security Level A1

 

Applications

  • On-site and laboratory calibration of temperature sensors, RTDs, thermocouples, and standard thermometers

  • Dry block mode: Quick, clean calibration without liquids

  • Wet calibration mode: For sensors requiring full immersion and enhanced thermal transfer

  • Used in cryogenics, chemical, pharmaceutical, food, machinery, and industrial laboratories

  • Ideal for portable, ultra-low temperature verification in demanding environments

What Is A Dry-Block Calibrator?

A dry-block calibrator, also known as a dry-well calibrator, is a device used to calibrate temperature measurement instruments such as thermocouples, thermometers, thermistors, and resistance temperature detectors (RTDs). Unlike other calibration methods that might use liquid baths, dry-block calibrators provide a stable and uniform temperature source in a dry environment.

How It Works

Heating/Cooling: The dry-block calibrator heats or cools a metal block to a precise temperature.

Insertion: The block has pre-drilled holes where temperature sensors or probes are inserted.

Stabilization: The calibrator stabilizes at the set temperature to ensure uniform heat distribution.

Measurement: The readings from the sensors are compared to the calibrator’s displayed temperature, and any discrepancies are noted and adjusted.

Applications

Dry-block calibrators are widely used in industries where precise temperature control is crucial, such as:

Pharmaceuticals: Ensuring medications are stored at correct temperatures.

Food and Beverage: Maintaining product quality and safety.

Manufacturing: Ensuring machinery and equipment function properly.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

DELIVERY TIMES

All orders, wherever possible are shipped the same day within the UK as long as it is received before 1 pm.

Orders placed on Friday after 1 pm or the weekend will be dispatched on Monday.

PACKAGING & SHIPMENT

  • Great care is take with each order to ensure they are packed securely to prevent any damage in transit.
  • We can ship orders in several boxes depending on quantity, size or types.
  • Each order is shipped with a packing note inside the box and a carrier shipping label on the outside.