Low Temperature Dry Block/Wet Calibrator (-50℃ ~ 140℃)

The Low Temperature Dry Block/Wet Calibrator (-50℃ to +140℃) delivers consistent, precise, and uniform temperature settings with rapid stabilization, making it highly efficient for both laboratory and field applications. Designed for portability and convenience, it is widely used for the calibration of temperature sensors, standard thermometers, thermocouples, thermal resistors, and dilatation thermometers.

By eliminating slow heat-up times and temperature inaccuracies often found in cheaper calibrators, the UCI-ST-AS-CAL provides faster calibration cycles, higher accuracy, and long-term reliability. Its advanced heating principle design, combined with rapid cooling and intuitive operation, ensures maximum efficiency and meets international calibration standards.

Key Features

  • Ultra-Wide Temperature Range: -50℃ to +140℃ for versatile calibration needs.

  • Dual-Mode Functionality: Supports both dry block calibration and wet calibration using inserts or liquid (e.g., anhydrous ethanol).

  • Fast Heat-Up & Cooling: Reaches maximum temperature in ~20 minutes and minimum temperature in ~45 minutes.

  • High Accuracy & Stability: ±0.2℃ accuracy and ±0.05℃ stability for reliable results.

  • Uniform Temperature Distribution: Axial uniformity within 1℃ (40 min) and radial uniformity 0.1–0.2℃.

  • Lightweight & Portable: Compact design (only 6–10kg) for easy transport.

  • Advanced Interface: LCD touch screen with simple, intuitive operation.

  • Data Management: Built-in data logging and USB interface for data export.

  • Automatic Switch Test: Automatic ramping and recording of switch points.

  • Safety & Compliance: Over-temperature and short-circuit protection, CE and RoHS certified.

Technical Specifications

Parameter Specification
Temperature Range -50℃ to +140℃
Accuracy ±0.2℃
Stability ±0.05℃
Axial Uniformity ≤ 1℃ within 40 min
Radial Uniformity 0.1℃ – 0.2℃
Resolution 0.01℃
Display LCD display (℃ / ℉)
Heating Time To +140℃ in approx. 20 minutes
Cooling Time To -50℃ in approx. 45 minutes
Block Depth 160mm
Insert Diameter 24.8mm, with interchangeable multi-hole inserts (3–12mm dia)
Stable Time 15 minutes
Dimensions 310 × 190 × 340 mm
Weight 6–10kg (depending on configuration)
Power Supply 100–115V AC ±10% or 200–230V AC ±10%, 50/60Hz, 575W
Fuse 115V: 6.3A T 250V / 230V: 3.15A T 250V
Operating Conditions 0℃ to +35℃, 30–80% RH (non-condensing), <2000m
Storage Conditions -20℃ to +60℃, 0–90% RH (non-condensing)
Certifications CE, RoHS compliant

Applications

  • On-site calibration of temperature sensors, thermocouples, RTDs, and thermometers

  • Quality control in pharmaceutical, food, machinery, and chemical industries

  • Dry block mode: Quick probe calibration without fluids

  • Wet calibration mode: For sensors requiring fluid immersion with higher thermal transfer

  • Industrial laboratories and service teams requiring portable, accurate calibration

What Is A Dry-Block Calibrator?

A dry-block calibrator, also known as a dry-well calibrator, is a device used to calibrate temperature measurement instruments such as thermocouples, thermometers, thermistors, and resistance temperature detectors (RTDs). Unlike other calibration methods that might use liquid baths, dry-block calibrators provide a stable and uniform temperature source in a dry environment.

How It Works

Heating/Cooling: The dry-block calibrator heats or cools a metal block to a precise temperature.

Insertion: The block has pre-drilled holes where temperature sensors or probes are inserted.

Stabilization: The calibrator stabilizes at the set temperature to ensure uniform heat distribution.

Measurement: The readings from the sensors are compared to the calibrator’s displayed temperature, and any discrepancies are noted and adjusted.

Applications

Dry-block calibrators are widely used in industries where precise temperature control is crucial, such as:

Pharmaceuticals: Ensuring medications are stored at correct temperatures.

Food and Beverage: Maintaining product quality and safety.

Manufacturing: Ensuring machinery and equipment function properly.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

DELIVERY TIMES

All orders, wherever possible are shipped the same day within the UK as long as it is received before 1 pm.

Orders placed on Friday after 1 pm or the weekend will be dispatched on Monday.

PACKAGING & SHIPMENT

  • Great care is take with each order to ensure they are packed securely to prevent any damage in transit.
  • We can ship orders in several boxes depending on quantity, size or types.
  • Each order is shipped with a packing note inside the box and a carrier shipping label on the outside.

What type of temperature calibrator do I need?

If your not sure which calibrator you need, this will help you to make a better selection of choice.