{"product_id":"unitrol-7000bgor-natural-gas-control-valve","title":"Unitrol 7000BGOR Natural Gas Control Valve Replacement – Flame Failure Safety Gas Valve","description":"\u003cdiv class=\"markdown markdown-main-panel enable-updated-hr-color\" id=\"model-response-message-contentr_a9e3e0dda0dd9ab3\" aria-live=\"polite\" aria-busy=\"false\" dir=\"ltr\"\u003e\n\u003cp data-path-to-node=\"1\"\u003eKeep your gas-fired equipment running at peak efficiency with the \u003cb data-path-to-node=\"1\" data-index-in-node=\"66\"\u003e7000BGOR Unitrol Gas Control Valve\u003c\/b\u003e. This valve is a versatile, high-reliability solution for a wide range of heating applications, including wall heaters, small furnaces, and boilers. Known for its compact footprint and legendary durability, the \u003cb data-path-to-node=\"1\" data-index-in-node=\"312\"\u003e7000BGOR\u003c\/b\u003e is a \"go-to\" for technicians and DIYers alike.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"3\"\u003e\u003cb data-path-to-node=\"3\" data-index-in-node=\"0\"\u003eProduct Highlights\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eMillivolt Actuated:\u003c\/b\u003e Self-powered operation via a thermopile\/generator—no external electricity or transformer required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eLow-Profile Design:\u003c\/b\u003e Specifically engineered to fit in tighter cabinets where larger valves might struggle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eIntegrated Pressure Regulator:\u003c\/b\u003e Factory-set for \u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"47\"\u003eNatural Gas\u003c\/b\u003e to ensure a steady, safe flame height.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eSimple Three-Position Control:\u003c\/b\u003e Features a high-visibility dial with \"PILOT,\" \"ON,\" and \"OFF\" settings for easy maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eReliable Safety Shut-off:\u003c\/b\u003e Includes a 100% safety shut-off feature that halts gas flow immediately if the pilot flame goes out.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003ctable data-path-to-node=\"7\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,1,0,0\"\u003e\u003cb data-path-to-node=\"7,1,0,0\" data-index-in-node=\"0\"\u003eGas Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,1,1,0\"\u003eNatural Gas (NG)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,2,0,0\"\u003e\u003cb data-path-to-node=\"7,2,0,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,2,1,0\"\u003e7000BGOR\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,3,0,0\"\u003e\u003cb data-path-to-node=\"7,3,0,0\" data-index-in-node=\"0\"\u003eInlet\/Outlet Size\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,3,1,0\"\u003e3\/4\" NPT, 11\/32\" T\/C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,4,0,0\"\u003e\u003cb data-path-to-node=\"7,4,0,0\" data-index-in-node=\"0\"\u003eCapacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,4,1,0\"\u003eStandard Capacity (Up to 100,000 BTU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,5,0,0\"\u003e\u003cb data-path-to-node=\"7,5,0,0\" data-index-in-node=\"0\"\u003ePressure Setting\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,5,1,0\"\u003e5.2\" W.C.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003ccode data-path-to-node=\"10,2,0\" data-index-in-node=\"18\"\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eQ: What is the difference between the 7000BGOR and the 7000BMVR?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"65\"\u003eA:\u003c\/b\u003e While both are millivolt valves, the \u003cb data-path-to-node=\"13\" data-index-in-node=\"105\"\u003eBGOR\u003c\/b\u003e is typically more compact and intended for standard-capacity residential appliances (like wall heaters), whereas the \u003cb data-path-to-node=\"13\" data-index-in-node=\"227\"\u003eBMVR\u003c\/b\u003e is often a higher-capacity \"Big Mag\" version for larger furnaces or commercial boilers. Always check your BTU requirements!\u003c\/p\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eQ: Does this include the thermocouple?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"39\"\u003eA:\u003c\/b\u003e No, this is the gas valve only. However, it features the standard screw-in port for a 30mV thermocouple or a coaxial connection for a thermopile, depending on your specific pilot setup.\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eQ: Can I install this myself?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"30\"\u003eA:\u003c\/b\u003e While the installation is straightforward, working with gas lines is inherently dangerous. We strongly recommend installation by a certified gas technician to ensure there are no leaks and that the manifold pressure is set correctly.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"0\"\u003eCompatibility Note\u003c\/b\u003e\u003c\/h4\u003e\n\u003cblockquote data-path-to-node=\"18\"\u003e\n\u003cp data-path-to-node=\"18,0\"\u003e\u003cb data-path-to-node=\"18,0\" data-index-in-node=\"0\"\u003eTech Tip:\u003c\/b\u003e The \"R\" in 7000BGOR stands for \u003cb data-path-to-node=\"18,0\" data-index-in-node=\"41\"\u003eRegulated\u003c\/b\u003e. If your existing valve does not have a regulator (a flat top without the adjustment screw tower), this regulated model is often a safer, more efficient upgrade for modern Natural Gas standards.\u003cb data-path-to-node=\"20\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":56049957339515,"sku":"AB007-BLEED","price":108.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0735\/5796\/6882\/files\/AB007bleed.jpg?v=1770205787","url":"https:\/\/www.undercontrol.co.uk\/products\/unitrol-7000bgor-natural-gas-control-valve","provider":"Under Control Instruments ","version":"1.0","type":"link"}