{"product_id":"unitrol-7000bmvr-lpg-gas-control-valve-propane","title":"Unitrol 7000BMVR Replacement LPG Gas Control Valve – Propane Flame Failure Safety Valve","description":"\u003cdiv class=\"markdown markdown-main-panel enable-updated-hr-color\" id=\"model-response-message-contentr_29da18bc28166b11\" aria-live=\"polite\" aria-busy=\"false\" dir=\"ltr\"\u003e\n\u003cp data-path-to-node=\"1\"\u003eEnsure your high-capacity heating system is running safely and efficiently with this \u003cb data-path-to-node=\"1\" data-index-in-node=\"85\"\u003e7000BMVR Unitrol Gas Control Valve\u003c\/b\u003e, specifically calibrated for \u003cb data-path-to-node=\"1\" data-index-in-node=\"149\"\u003eLiquid Propane (LPG)\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eDesigned for heavy-duty applications like large furnaces, boilers, and commercial heaters, this millivolt valve is factory-set to the standard \u003cb data-path-to-node=\"2\" data-index-in-node=\"143\"\u003e11\" W.C. (Water Column)\u003c\/b\u003e pressure required for Propane systems. It’s the ultimate \"drop-in\" solution for those needing a high-flow, self-powered gas control.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"4\"\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"0\"\u003eKey Features\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eFactory-Set for Propane:\u003c\/b\u003e Pre-configured for LPG with a high-pressure regulator set to \u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"86\"\u003e11\" W.C.\u003c\/b\u003e for optimal combustion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eHigh-Capacity \"Big Mag\" Design:\u003c\/b\u003e The BMVR series is built for higher BTU outputs, making it ideal for demanding residential and commercial equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eSelf-Powered Millivolt System:\u003c\/b\u003e No external power required. This valve uses the millivoltage from a thermopile to operate, ensuring heat even during power outages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eUser-Friendly Control:\u003c\/b\u003e Features the iconic large red \"ON\/OFF\" dial for easy operation and clear status identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eSafety First:\u003c\/b\u003e Equipped with a 100% safety shut-off system; gas flow stops instantly if the pilot flame is lost.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003e\u003cb data-path-to-node=\"8,1,0,0\" data-index-in-node=\"0\"\u003eGas Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eLiquid Propane (LPG)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003e\u003cb data-path-to-node=\"8,2,0,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003e7000BMVR-LP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003e\u003cb data-path-to-node=\"8,3,0,0\" data-index-in-node=\"0\"\u003ePressure Setting\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003e\u003cb data-path-to-node=\"8,3,1,0\" data-index-in-node=\"0\"\u003e11.0\" W.C.\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003e\u003cb data-path-to-node=\"8,4,0,0\" data-index-in-node=\"0\"\u003eControl Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003eMillivolt (Standing Pilot)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003e\u003cb data-path-to-node=\"8,5,0,0\" data-index-in-node=\"0\"\u003eInlet\/Outlet Size\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e3\/4\" NPT (High-Flow)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eQ: Can I use this valve with Natural Gas?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"42\"\u003eA:\u003c\/b\u003e No. This model is specifically regulated for \u003cb data-path-to-node=\"14\" data-index-in-node=\"90\"\u003ePropane (LPG)\u003c\/b\u003e at 11\" W.C. Using this on a Natural Gas system will cause dangerously high flames and soot buildup.\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eQ: Is the 11\" W.C. pressure adjustable?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"40\"\u003eA:\u003c\/b\u003e While there is a regulator adjustment screw under the cap, it is factory-set to 11\" W.C. for Propane. Adjustments should only be made by a pro with a manometer to ensure safe manifold pressure.\u003c\/p\u003e\n\u003cp data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eQ: Does this replace the standard 7000BMVR used in Natural Gas furnaces?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"73\"\u003eA:\u003c\/b\u003e Yes, provided you are converting the appliance to Propane or replacing an existing Propane valve. The physical footprint and wiring are identical to the NG version.\u003c\/p\u003e\n\u003cblockquote data-path-to-node=\"18\"\u003e\n\u003cp data-path-to-node=\"18,0\"\u003e\u003cb data-path-to-node=\"18,0\" data-index-in-node=\"0\"\u003e⚠️ WARNING:\u003c\/b\u003e Gas conversions and replacements should only be performed by a licensed gas technician. \u003cspan class=\"citation-23 citation-end-23\"\u003eImproper installation can result in fire, explosion, or carbon monoxide poisoning.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e Always perform a gas leak test after installation.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":56050622431611,"sku":"AB007-MV LPG","price":108.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0735\/5796\/6882\/files\/AB007b_0aec93f9-6ece-4c4d-af20-9618733906af.jpg?v=1770208546","url":"https:\/\/www.undercontrol.co.uk\/fr\/products\/unitrol-7000bmvr-lpg-gas-control-valve-propane","provider":"Under Control Instruments ","version":"1.0","type":"link"}