{"product_id":"k-type-thermocouple-5x50mm-2m-ptfe-leads","title":"K-Type Thermocouple Probe 5 x 50mm – Insulated Stainless Steel Sensor with 2m PTFE Twin Flat Lead","description":"\u003cp\u003eThe \u003cstrong\u003eK-Type Thermocouple 5 x 50mm\u003c\/strong\u003e is a robust temperature sensor designed for accurate and reliable temperature measurement across a wide range of heating and industrial applications.\u003c\/p\u003e\n\u003cp\u003eThe sensor features a \u003cstrong\u003e5mm diameter x 50mm long insulated probe\u003c\/strong\u003e, providing a compact and durable sensing solution where a protected probe is preferred. The probe is supplied with \u003cstrong\u003e2 metres of PTFE-insulated twin flat thermocouple cable\u003c\/strong\u003e, allowing the sensor to be positioned away from the temperature controller or measuring instrument.\u003c\/p\u003e\n\u003cp\u003eThe flexible PTFE cable is well suited to applications where good heat resistance and reliable insulation are required. K-Type thermocouples are widely used with compatible temperature controllers, digital thermometers, PID controllers and temperature monitoring equipment. PTFE-insulated K-Type thermocouple leads are commonly supplied for industrial and test-and-measurement applications.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eK-Type thermocouple\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProbe size:\u003c\/strong\u003e 5mm diameter x 50mm length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInsulated probe construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2 metre cable length\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePTFE-insulated twin flat leads\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact and robust design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for temperature sensing and control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with K-Type thermocouple instruments and controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for replacement or new installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for industrial, commercial and general temperature measurement applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTypical Applications\u003c\/h4\u003e\n\u003cp\u003eThis K-Type thermocouple can be used for temperature sensing in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial heating equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOvens and furnaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommercial catering equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFood processing machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeating systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePID temperature controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial process equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery and equipment temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLaboratory and test equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral-purpose temperature measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK-Type Thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLead Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLead Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwin flat leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermocouple mV signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwin lead wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature measurement \u0026amp; control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eWhy Choose a K-Type Thermocouple?\u003c\/h4\u003e\n\u003cp\u003eK-Type thermocouples are one of the most widely used thermocouple types for general temperature measurement. They are suitable for use with a broad range of temperature controllers, meters and monitoring systems designed for K-Type inputs.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e5 x 50mm probe\u003c\/strong\u003e provides a good balance between durability and compact installation, while the \u003cstrong\u003e2m PTFE twin flat lead\u003c\/strong\u003e provides convenient reach between the sensor and connected control or measurement equipment.\u003c\/p\u003e\n\u003ch4\u003eInstallation \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp\u003eBefore ordering, check that your existing equipment requires a \u003cstrong\u003eK-Type thermocouple\u003c\/strong\u003e and that the probe dimensions, lead configuration and connection arrangement are suitable for your application.\u003c\/p\u003e\n\u003cp\u003eThe thermocouple should be connected with the correct polarity and to an instrument specifically configured for \u003cstrong\u003eK-Type thermocouple input\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Under Control Instruments","offers":[{"title":"Default Title","offer_id":56403773456763,"sku":"K5-50-2M","price":8.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0735\/5796\/6882\/files\/Kthermocouple4x40green.jpg?v=1788453443","url":"https:\/\/www.undercontrol.co.uk\/fr\/products\/k-type-thermocouple-5x50mm-2m-ptfe-leads","provider":"Under Control Instruments ","version":"1.0","type":"link"}